    1. CABLE CONSTRUCTION

    1.1. CROSS SECTIONAL DIAGRAM

    2. TECHNICALSPECIFICATION

    2.1. TECHNICALSPECIFICATION

    Fiber count

    12F

    OD of Loose tubemm

     2.6±0.1

    Max fiber count/tube

    12

    NO. of Tube

    1

    FRP/Coatmm

    2

    PE sheath Thicknessmm

    1.5

    OD of cable (mm)

    7.8±0.4

    Net weight ( kg/km)

    53


    2.2 TEMPERATURE RANGE

    Operating temperature

     -40℃~+65℃

    Store/Transport temperature

    -50℃~+70℃

    Installation temperature

     -20℃~+65℃


    3. FIBERAND LOOSE BUFFER TUBE IDENTIFICATION

    4. OPTICAL FIBER

    4.1 The Optical and Geometrical Performance of Single Mode Fiber (ITU-T G652D)

    Items

    UNITS

    SPECIFICATION

    Fiber type

    -

    G652D

    Attenuation

     dB/km

    ≤ 0.36 at 1310nm

    ≤ 0.25 at 1550nm

    ≤ 0.36 at 1625nm

    Chromatic Dispersion

    ps/nm.km

    ≤ 3.5 at 1310nm

    ≤ 20 at 1550nm

    ≤ 22 at 1625nm

    Zero Dispersion Slope

    ps/nm² .km

    0.093

    Zero Dispersion Wavelength

    nm

    1300 ~ 1324

    PMD (M=20, Q=0.01%)

    ps/√km

    ≤ 0.2

    Cut-off Wavelength ( λcc)

    nm

    ≤ 1260

    Attenuation vs. Bending( 60mm x 100 turns )

    dB

    ≤ 0.1 at 1625nm

    Mode Field Diameter@ 1310nm

    μ m

    (8.6-9.5) ± 0.7

    Core-Clad Concentricity

    μ m

    ≤ 0.5

    Cladding Diameter

    μ m

    125±1

    Cladding Non-circularity

    %

    ≤ 0.8

    Coating Diameter

    μ m

    245±5

    Proof Test

    Gpa

    ≥ 0.70

    Temperature Dependence

    dB

    ≤ 0.5 (-60℃ to +85℃)


    5. Mechanical and Environmental Performance of the Cable

    NO.

    ITEM

    METHOD

    ACCEPTANCE CRITERIA

    1

    Tensile Loading Test

    #Test method:NBR 13512

    -. Attenuation increment@1550nm:

    -. Long-tensile load:750N

    ≤0.1dB

    -. Short-tensile load:1300N

    -. No jacket cracking and fiber

    -. Cable length:≥50m

    breakage

    2

    Crush Resistance Test

    #Test method:NBR 13507

    -. Attenuation increment@1550nm:≤0.1dB

    -.Long load:1000 N/100mm

    -. No jacket cracking and fiber breakage

    -.Short load:2000 N/100mm

    Load time:1 minutes

    3

    Impact Resistance Test

    #Test method:NBR 13509

    -. No fiber breakage

    25 cycles, P = NBR 14160

    4

    Repeated Bending

    #Test method:NBR 13518

    -. Attenuation increment@1550nm:

    -.Mandrel diameter : 6D (D =cable diameter)

    ≤0.1dB

    -.Subject weight:2kg

    -.Bending frequency:50 cycles

    5

    Torsion Test

    #Test method:NBR 13513

    -. Attenuation increment@1550nm:≤0.1dB

    -.Length:1m

    -. No jacket cracking and fiber breakage

    -.Subject weight:25kg

    -.Angle:±180 degree

    -.Frequency:≥10/point

    6

    Water Penetration Test

    #Test method:NBR 9136

    -. No leakage through the open cable end

    -.Height of pressure head:1m

    -.Length of specimen:3m

    -.Test time: 24 hours

    7

    Temperature Cycling Test

    #Test method:NBR 13510

    -. Attenuation increment@1550nm: ≤0.1dB

    -.Temperature steps:+20℃、

    -. No jacket cracking and fiber breakage

    20℃、+65℃、+20℃

    -.Testing Time:24 hours/step

    -.Cycle index:2



    5.2 FIBER OPTIC CABLE BENDING RADIUS

    Static bending:

      ≥ 10times than cable out diameter

     Dynamic bending:

      ≥ 20times than cable out diameter.


    6. PACKAGE AND MARK

    6.1 PACKAGE

    Not allowed two length units of cable in one drum, two ends should be sealed,. Two ends should be packed inside drum, reserve length of cable not less than 3 meters.